OPERATOR MANUAL
AUTO LENSMETER
TL-100
HOLD
• Read this Operator Manual carefully before using this instrument in order to operate it
properly and safely.
• Do not use procedures other than those specified in this manual.
• Keep this Operator Manual handy when operating this instrument.
• For any questions about this instrument or about this manual, contact your local TOMEY
representative.
SYMBOLS USED IN THIS MANUAL
The symbols used in this manual represent the following messages:
• This is a precaution that, if unheeded, will result in a hazard-
ous situation where there is an imminent danger of serious
injury or death.
• This is precaution that, if unheeded, could result in a hazard-
ous situation where there is a possibility of serious injury or
death.
• This is a precaution that, if unheeded, may result in a situa-
tion where there is a possibility of minor or moderate injury or
damage to property.
• This is an additional instruction which may contain a special
precaution on company policy related, either directly or indi-
rectly, to the safety of personnel or to the protection of prop-
erty.
SYMBOLS USED IN THIS MANUAL
i
CONTENTS
1. PRIOR TO USE ………………………………………………. 1-1
1.1 Cautionary notes ……………………………………………………….1-1
1.2 Unpacking ………………………………………………………………..1-3
1.3 Explanation of terms …………………………………………………..1-4
1.4 Outline of operation ……………………………………………………1-5
2. COMPONENT LIST AND FUNCTIONS ……………… 2-1
2.1 Front ………………………………………………………………………..2-1
2.2 Back ………………………………………………………………………..2-2
2.3 Screen layout ……………………………………………………………2-3
3. METHOD OF OPERATION ………………………………. 3-1
3.1 Preparation for operating …………………………………………….3-1
3.2 Measuring methods ……………………………………………………3-3
3.2.1 Measuring single vision lenses …………………………………. 3-3
a) Automatic hold mode …………………………………………… 3-3
b) Manual hold mode ………………………………………………. 3-5
3.2.2 Measuring multi-focal lenses (PROG mode)……………….. 3-7
a) Measuring progressive addition lenses…………………… 3-7
b) Measuring bifocal lenses ……………………………………. 3-12
3.2.3 Measuring prism……………………………………………………. 3-15
3.2.4 Measuring high index lenses (HI mode)……………………. 3-16
3.2.5 Measuring contact lenses (CL mode) ………………………. 3-17
3.2.6 Recalling the readings (READING) ………………………….. 3-19
3.2.7 Detecting progressive lenses ………………………………….. 3-20
3.3 Operating the clamp, marking device and lens table …….3-21
3.3.1 Clamp ………………………………………………………………….. 3-21
3.3.2 Marking device ……………………………………………………… 3-22
3.3.3 Lens table…………………………………………………………….. 3-23
3.4 Setup ……………………………………………………………………..3-24
3.5 LCD contrast adjustment …………………………………………..3-28
3.6 Automatic power saving function (AUTO POWER OFF) 3-29
4. MAINTENANCE AND INSPECTION ………………….. 4-1
4.1 Warranty …………………………………………………………………..4-1
4.2 Routine maintenance …………………………………………………4-2
4.2.1 Cleaning cover glass ……………………………………………….. 4-2
4.3 Replacing spare parts ………………………………………………..4-3
4.3.1 Fuse ……………………………………………………………………… 4-3
4.3.2 Ink cartridge …………………………………………………………… 4-4
ii
CONTENTS
4.4 Storage………………………………………………………………….. 4-6
4.5 Packing materials ……………………………………………………. 4-6
5. TROUBLESHOOTING ……………………………………… 5-1
5.1 Troubleshooting guide ……………………………………………….. 5-1
5.1.1 General operation …………………………………………………….. 5-1
5.1.2 Progressive addition lens measurement………………………. 5-3
5.2 Error messages …………………………………………………………5-7
6. SPARE PARTS ……………………………………………….. 6-1
7. SPECIFICATIONS …………………………………………… 7-1
7.1 Measurement ……………………………………………………………7-1
7.2 Data control ………………………………………………………………7-1
7.3 Physical dimensions and electrical requirements ……………7-1
7.4 Environmental conditions …………………………………………… 7-2
7.5 Approved international standards …………………………………7-2
8. INDEX ……………………………………………………………. 8-1
CONTENTS
iii
( This page is left intentionally blank )
iv
1. PRIOR TO USE
• Read this Operator Manual carefully before using this
instrument in order to operate it properly and safely.
• Do not use procedures other than those specified in this
manual.
1.1 CAUTIONARY NOTES
• Never install this instrument near locations where explosive
or flammable materials are used or stored. Such installation
may result in a fire or an explosion.
• Only well-trained personnel should operate this instrument.
• When installing this instrument, observe the following items.
— Do not install this instrument in a location where it might be
exposed to water or chemicals.
— Do not install this instrument in a location where it might be subject
to adverse influences, such as excessive atmospheric pressure,
high temperature, excessive humidity, poor ventilation, direct
sunlight, dust, salt or sulfur in the air.
— Ascertain that factors such as excessive slope, vibration and
impact will not endanger the instrument (including during
transportation).
— Do not install this instrument near the storage of chemical
substances or in a location where gas may be generated.
— Adhere to the specified mains frequency, voltage and allowable
current (or allowable power consumption).
• During use of this instrument, observe the following:
— Do not move a coated lens when it is held with the clamp. This
may result in damage to the coating. The clamp should be used
only for marking.
— Clean the cover glass under the nose piece often with a soft cloth.
— Always keep the tip of the nose piece clean. Dust on it may result
in scratches on a lens.
1.1 CAUTIONARY NOTES
1-1
• When this instrument is not in use, keep the dust cover over
it.
• When the instrument is not used for an extended period of
time, unplug the power cord.
• After using this instrument, observe the following:
— Do not apply excessive force when unplugging the cords.
— Refer to the Section 4.4 Storage for storage instructions.
• If you suspect that this instrument is not functioning properly,
do not attempt to repair it. Contact your Tomey
representative or local distributor.
• Do not modify this instrument.
• Maintenance:
— Inspect this instrument and its accessories periodically.
— If this instrument has been idle for a long period of time, confirm
that it is functioning properly and safely before using it again. For
this, TOMEY recommends using a trial lens set for checking
accuracy.
• Due to vibration during transport and/or environmental
changes of storage, the ink may leak out of the marking
device cartridge. If you find an ink stain and/or leakage of ink
at the tip of the marking device, wipe it off and make sure it is
functioning properly.
1-2
1.1 CAUTIONARY NOTES
1.2 UNPACKING
Upon unpacking, inspect that all the components are present and that there is no
visible damage to any of them.
If there are any missing or damaged items, immediately contact your Tomey
representative or local distributor.
• Be sure to retain all shipping and packing materials for reuse
if the instrument will be transported or shipped.
COMPONENT
• Main unit of the AUTO LENSMETER TL-100 …….. 1
H
O
L
D
• Power Cord ……………………………………………………….. 1
• Contact Lens Nose Piece …………………………………….. 1
• Spare Fuse (250V, 2.0A) …………………………………….. 1
• Dust Cover………………………………………………………… 1
• Operator Manual (this book) ……………………………….. 1
1.2 UNPACKING
1-3
1.3 EXPLANATION OF TERMS
• D…………………………………….. Diopter (a unit of measurement referring to the refractive power
of a lens; reciprocal of the focal length of the lens in meters)
• ∆…………………………………….. Prism diopter (a unit of the measurement of angular deviation
of light produced by a lens)
• SPH (S) …………………………… Spherical refractive power (unit: D, diopter)
• CYL (C) ………………………….. Cylindrical refractive power (unit: D, diopter)
• AXIS (A)…………………………. The position of minimum or maximum power in a lens that has
cylinder power. Axis is measured in degrees and is used to
specify the orientation of a lens to correct astigmatism. (unit:
degree)
• ADD ……………………………….. Additional power of a multi-focal lens (including a progressive
addition lens).
• CL ………………………………….. Contact lens
• HI mode ………………………….. Measurement mode for high index lens
• Abbe number……………………. Number indicating the dispersive power of a lens. The Abbe
number of normal lenses is about 60 and that of high index
lenses ranges from approximately 30 to 45.
• PSM ……………………………….. Prism
1-4
1.3 EXPLANATION OF TERMS
1.4 OUTLINE OF OPERATION
The AUTO LENSMETER TL-100 is an instrument for the
automatic measurement of refractive and prism power of
spectacles and contact lenses.
The TL-100 is composed of a built-in optical system, an
electronic processing system, and a mechanical system.
Placing spectacles or contact lenses on the nose piece initiates
automatic measurement. The results are displayed on the LCD.
1.4 OUTLINE OF OPERATION
1-5
( This page is left intentionally blank )
1-6
2. COMPONENT LIST AND FUNCTIONS
2.1 FRONT
Clamp
Stabilizes the lens when marking it.
Marking device
Marks the center and axis orientation of the
lens.
Nose piece
Lens is placed on the nose piece.
Lens table
Used to standardize the orientation of spectacles for accurate cylinder axis measurement
and vertical prism measurement.
HOLD button
Used for holding and storing the data.
H
O
L
D
MODE button
Selects single vision lens mode, multi-focal
lens mode or contact lens mode.
Contrast adjuster
Adjusts the contrast of the LCD.
READING button
Displays the stored data.
LCD
Liquid Crystal display displays information
such as centering of lens, measurement conditions and results.
2.1 FRONT
2-1
2.2 BACK
AUTO LENSMETER TL-100
100-240V~ 50/60Hz 35VA
MANUFACTURER
S/N
NAME: TOMEY CORPORATION
ADDRESS: 2-11-33 Noritakeshinmachi,
Nishi-ku, Nagoya 451-0051 Japan
ON
T2A 250V
OFF
Name plate
Shows the serial number.
AC power terminal
The accompanying power cord is connected to this
terminal.
Fuse holder
The fuse is mounted in this holder.
Power switch
Turns the power on or off.
2-2
2.2 BACK
2.3 SCREEN LAYOUT
Indication of the automatic
measurement mode
[AUTO]: Automatic measurement mode
Holding data
[HOLD]: Indicates the data are
being held.
Alignment screen
Used for centering the lens
Lens modes
Single vision lens mode:
Multi-focal lens mode:
Contact lens mode:
Measuremet Condition
AUTO
HOLD
HI
ERROR
L R
SPH CYL AXIS ADD
High index lens mode
MODE
CYL
STEP
PRISM
Indication of an ERROR
PRISM AXIS
BU
BD
Data area
The reading is displayed.
BO
BI
The lens to be measured
R: Right lens
L: Left lens
2.3 SCREEN LAYOUT
2-3
( This page is left intentionally blank )
2-4
3. METHOD OF OPERATION
3.1 Preparation for operating
• Before turning on the power, check the following items:
— Make sure that the cover glass under the nose piece is clean.
— Make sure that the nose piece seated properly.
— Make sure a lens is not on the nose piece.
Nose piece
Cover glass
H
O
L
D
1) Connect the female end of the power cord into the power terminal on
the back of the TL-100 and the male end into a 3-prong power
outlet.
2) Turn the power switch ON.
3) The initial screen will appear for approximately five seconds.
3.1 PREPARATION FOR OPERATING
3-1
4) The measurement screen will appear.
AUTO
MODE
CYL
STEP
R
SPH CYL AXIS ADD
• Do not place a lens onto the nose piece until after the
measurement screen appears.
• Turning the instrument on with the lens already on the
nose piece initiates a beep and indicates «INITIAL ERROR»
on the LCD. Remove the lens from the nose piece, then
press any button to proceed.
ERROR
3-2
3.1 PREPARATION FOR OPERATING
3.2 MEASURING METHODS
3.2.1 MEASURING SINGLE VISION LENSES
If the instrument is not in Single Vision mode ( ), change to
Single Vision mode by pressing the MODE button. Single Vision
mode ( ), Multi-focal mode ( ) and Contact Lens mode ( )
are set consecutively each time the MODE button is pressed.
a) Automatic Hold Mode
In the automatic hold mode, readings are automatically held when
the lens is properly aligned.
• Thrusting a lens onto the nose piece or moving a lens
quickly may result in damage to the lens.
1) If the instrument is in manual hold mode and you wish to use
automatic (AUTO) hold mode, press the HOLD button for
approximately 1 second until «AUTO» appears at the upper left of
the screen.
AUTO
HOLD
MODE
CYL
STEP
R
SPH CYL AXIS ADD
2) Place the right lens on the nose piece with the bottom of the frame
away from you and the temple downward (as shown below).
H
3.2 MEASURING METHODS
3-3
• The right lens must be measured first and then the left lens.
3) Move the lens gently right and left, back and forth to center the
cursor (+) on the crosshair. The reading will be displayed in real
time.
4) When alignment is achieved, a beep will sound and the reading will
be automatically held.
AUTO
HOLD
MODE
CYL
STEP
R
SPH CYL AXIS ADD
5) When the right lens is removed from the nose piece, the instrument
is ready to measure the left lens.
6) Place the left lens on the nose piece as described in step 2 and
follow steps 3-4.
• When the left lens is placed on the nose piece, «HOLD» will
disappear from the screen. However, the right lens data will
3-4
be retained, and if the Output button is pressed after
measuring the left lens, data for both lenses will be
displayed.
3.2 MEASURING METHODS
b) Manual Hold Mode
• Thrusting the lens onto the nose piece or moving the lens
quickly may result in damage to the lens.
1) If the instrument is in automatic (AUTO) hold mode and you wish
2) Place the right lens on the nose piece with the bottom of the frame
• The right lens must be measured first and then the left
lens.
to change to manual hold mode, press the HOLD button (located
below the nose piece) for approximately 1 second, until «AUTO»
disappears from the display.
away from you and the temples downward (as shown on page 3-3).
MODE
CYL
STEP
R
SPH CYL AXIS ADD
3) Move the lens gently right and left, back and forth to center the
cursor (+) on the crosshair. The reading will be displayed in the
data area in real time.
3.2 MEASURING METHODS
3-5
4) When alignment is achieved, press the HOLD button. The reading
will be held, and «HOLD» will be displayed at the top left of the
screen.
AUTO
HOLD
MODE
CYL
STEP
R
SPH CYL AXIS ADD
5) When the right lens is removed from the nose piece, the instrument
is ready to measure the left lens.
6) Place the left lens on the nose piece as described in step 2 and
follow steps 3-4.
• When the left lens is placed on the nose piece, «HOLD» will
disappear from the screen. However, the right lens data will
be retained, and if the Output button is pressed after
measuring the left lens, data for both lenses will be
displayed.
3-6
3.2 MEASURING METHODS
Loading…
Tomey TL 100 Auto Lensmeter User Manual
- Addeddate
- 2020-05-20 06:40:50
- Classification
- Clinical;Optometry;Tomey Optometry;Tomey TL-100
- Identifier
- manual_Tomey_TL-100_Auto_Lensmeter_User_Manual
- Identifier-ark
- ark:/13960/t1ck75w73
- Ocr
- ABBYY FineReader 11.0 (Extended OCR)
- Ppi
- 300
- Scanner
- Internet Archive Python library 1.9.0
comment
Reviews
There are no reviews yet. Be the first one to
write a review.
231
Views
DOWNLOAD OPTIONS
Temporarily Unavailable
DAISY
For users with print-disabilities
Temporarily Unavailable
EPUB
Uploaded by
Sketch the Cow
on
FAQ: Types of Manuals and Their Contents
Tomey TL-100 Manuals come in various types, each serving a specific purpose to help users effectively operate and maintain their devices. Here are the common types of Tomey TL-100 User Guides and the information they typically include:
- User Manuals: Provide comprehensive instructions on how to use the device, including setup, features, and operation. They often include troubleshooting tips, safety information, and maintenance guidelines.
- Service Instructions: Designed for technicians and repair professionals, these manuals offer detailed information on diagnosing and repairing issues with the device. They include schematics, parts lists, and step-by-step repair procedures.
- Installation Guides: Focus on the installation process of the device, providing detailed instructions and diagrams for proper setup. They are essential for ensuring the device is installed correctly and safely.
- Maintenance Manuals: Provide guidance on routine maintenance tasks to keep the device in optimal condition. They cover cleaning procedures, part replacements, and regular servicing tips.
- Quick Start Guides: Offer a concise overview of the essential steps needed to get the device up and running quickly. They are ideal for users who need immediate assistance with basic setup and operation.
Each type of Tomey TL-100 instruction is designed to address specific needs, ensuring users have the necessary information to use, maintain, and repair their devices effectively.
Related Instructions for Tomey TL-100:
2
SP-100
Service manual SP-100 (Medical Equipment ePDF Manual, #5Y6AP3)
21
1417
312
4
AL-2000
Operator’s manual PDF User Manual (@3X8L7G), Tomey AL-2000 Medical Equipment (25/01/2025)
119
598
108
5
AL-100
Service manual PDF Manual (@6W93X2), Tomey AL-100 Medical Equipment (13th Nov 2024)
16
389
74
7
Z Series
Operator’s manual #8DF1EX: Z Series Medical Equipment Operator’s manual
14
491
74
8
UD-600
Operator’s manual #C9QSWB: UD-600 Medical Equipment Operator’s manual
262
684
130
10
TCP-2000P
Operation manual #1YRJ4B: TCP-2000P Medical Equipment Operation manual
113
1208
242
Medical Equipment Devices by Other Brands:
Otto Bock 4R212 User Manual Manual Otto Bock Medical Equipment User manual manual (File: otto-bock-4r212-user-manual-manual-152, 04/01/2025) 4R212 04 Jan 2025 | 152 |
|
DeVilbiss 515A Series Instruction Manual 515A Series Instruction manual — 4X95UP 12 May 2025 | 52 |
|
AmeriWater MRO3 Operation & Maintenance Manual MRO3 Operation & maintenance manual — V7TNME MRO 3 and MRO4 MANUAL 17 Mar 2025 | 54 |
|
FP Optiflow junior OPT312 Application Manual FP Medical Equipment Application manual (File: fp-optiflow-junior-opt312-application-manual-2, Mon 12.2024) www.fphcare.com 23 Dec 2024 | 2 |
Categories:
Medical Equipment
Document Download |
‹
›
Tomey TL-100 Manual Online:
3.05,
2410
votes
Tomey TL-100 User Manual
Tomey TL-100 User Guide
Tomey TL-100 Online Manual
Text of Tomey TL-100 User Guide:
Related Products and Documents (Medical Equipment):
-
ReBuilder Medical Universal Conductive Garment Socks Medical Equipment Information booklet
Universal Conductive Garment Socks
rebuilder-medical/universal-conductive-garment-socks.pdf, 2 -
Tomey UD-600 Medical Equipment Operator’s manual
UD-600
tomey/ud-600.pdf, 262 -
Hitachi EUP-B512 Medical Equipment Instruction manual
EUP-B512
hitachi/eup-b512.pdf, 37 -
Welch Allyn 58014 Medical Equipment Mounting instructions
58014
welch-allyn/58014.pdf, 2 -
Watermark Medical ARES 610 Medical Equipment Product manual
ARES 610
watermark-medical/ares-610.pdf, 24 -
Drive TSE 120 Medical Equipment Operating instructions manual
TSE 120
drive/tse-120.pdf, 12 -
Haag-Streit BX 900 Medical Equipment User manual manual
BX 900
haag-streit/bx-900.pdf, 26 -
Pressalit Care R8400 Medical Equipment Mounting instruction
R8400
pressalit-care/r8400.pdf, 20
Comparable Devices:
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Alcatel | One Touch Spop 5035Y | Operation & user’s manual | alcatel/one-touch-spop-5035y-87P.pdf | 15 Jan 2025 | 76 | 10.32 Mb |
2 | NetComm | HSPA+ M2M | Operation & user’s manual | netcomm/hspa-m2m-9TL.pdf | 17 Oct 2023 | 16 | |
3 | Razor | Storm A | Owner’s manual | razor/storm-a-I8A.pdf | 08 Aug 2024 | 6 | |
4 | Motorola | ATRIX 2 | Quick start manual | motorola/atrix-2-7FN.pdf | 18 Oct 2023 | 2 | |
5 | Waring | CU-55 | Instruction book | waring/cu-55-5DR.pdf | 03 Oct 2023 | 10 | 0.25 Mb |
6 | Master | B 3,3 ECA | Owner’s manual | master/b-33-eca-CDQ.pdf | 10 Mar 2025 | 36 |
Similar Resources:
Medical Equipment Instructions:
-
Epson All in One Printer ET-4500
Manual: Epson ET-4500 (67HKG7, Upd.Tue 03.2025)
ET-4500, 4
-
ProForm Other 450 Hr Elliptical
ProForm 450 Hr Elliptical Manual (Manual ), @N4F7I2
450 Hr Elliptical, 20
-
Portwell Motherboard ROBO-8120VG2R
#K7IXI7 ROBO-8120VG2R: Portwell Motherboard Owner Documentation
ROBO-8120VG2R, 70
-
American Dynamics Security System DV8000
Guide: American Dynamics DV8000 (RP64H2, Upd.10/02/2025)
DV8000, 155
-
MUSIC HALL CD Player cd25.2
MUSIC HALL cd25.2 CD Player Operation & user’s manual
cd25.2, 8
-
JVC Car Speakers CS-GW1200F
JVC Product User Guide: CS-GW1200F PDF Instructions — 9GI58Y
CS-GW1200F, 2
-
DK Digital Clock PU-500
#9GM68M PU-500: DK Digital Clock Owner Documentation
PU-500, 8
-
ASUSTOR Network Hardware AS5002T
ASUSTOR AS5002T User Manual (Quick installation manual), @6667EW
AS5002T, 23
-
Skope Chiller SK1000
Chiller #Q5KDO1
SK1000, 37
-
Jensen TV DVD Combo CV2017J
PDF User Manual (@9M4FMJ), Jensen CV2017J TV DVD Combo (11th Oct 2024)
CV2017J, 32
-
Planet Network Router SG-4800
Planet Network Router Quick installation manual (File: planet-sg-4800-quick-installation-manual-12, 07.03.2025)
SG-4800, 12
-
jWIN CD Player JX-CD7160
jWIN Product User Guide: JX-CD7160 PDF Instruction manual — RE3465
JX-CD7160, 16
Comments, Questions and Opinions:
Specifications:2397/2397801-tl100.pdf file (04 Dec 2024) |
Rating:
Rated: 4.1 by 84 users, Data: UPD 4th December 2024
Tomey TL-100 Medical Equipment PDF Operator’s Manual (Updated: Wednesday 4th of December 2024 01:57:27 AM)
Compatible devices: H Series, TCP-2000, TSL-7000Hdigital, SP-100, MR-6000, UD-600, TCP-2000P, AL-100.
Recommended Documentation:
Text Version of Tomey TL-100 Operator’s Manual
(Ocr-Read Summary of Contents Tomey TL-100 Medical Equipment Document (Main Content), UPD: 04 December 2024)
-
63, 7-2 7.4 ENVIRONMENTAL CONDITIONS • Installation site: indoors • Operating temperature range: +10°C to + 40°C (+50 °F to +104°F) maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C • Main supply …
-
8, 1-3 1.2 UNPACKING Upon unpacking, inspect that all the components are present and that there is no visible damage to any of them. If there are any missing or damaged items, immediately contact your Tomey representative or local distributor. • Be sure to retain all sh…
-
24, Tomey TL-100 3-9 3) Measure the Distance Zone a. Move the lens away from you to place the distance zone over the nose piece. Move the lens gently right and left, back and forth to align the cursor (+) on the crosshair. AUTO MODE CYL STEP R SPH CYL AXIS ADD b. If AUTO HOLD…
-
28, 3-13 4) Measure the Distance Zone a. Move the lens gently right and left, back and forth to align the cursor («+» mark) on the crosshair. b. If AUTO HOLD is ON, when the cursor is aligned, a beep will sound, and the reading of the distance zone will be held aut…
-
21, 3-6 4) When alignment is achieved, press the HOLD button. The reading will be held, and «HOLD» will be displayed at the top left of the screen. MODE CYL STEP SPH CYL AXIS ADD R HOLD AUTO 5) When the right lens is removed from the nose piece, the inst…
-
35, Tomey TL-100 3-20 • If no readings have been stored, nothing will be displayed when the READING button is pressed. • To return to the measurement display, remove the lens from the nose piece and either place a lens on the nose piece again or press any button, except the READING but…
-
22, Tomey TL-100 3-7 3.2.2 MEASURING MULTI-FOCAL LENSES (MULTI-FOCAL MODE) The MULTI-FOCAL mode is used for measuring both progressive addition lenses and bi-focal lenses. • Refer to the Section 5.1 «Troubleshooting guide» for details of measuring in the MULTI-FOCAL mode. �…
-
17, 3-2 4) The measurement screen will appear. AUTO MODE CYL STEP R SPH CYL AXIS ADD • Do not place a lens onto the nose piece until after the measurement screen appears. • Turning the instrument on with the lens already on the nose piece initiates a beep and …
-
40, 3-25 3.4 SETUP d. ABBE NUMBER The Abbe number in the normal mode is 60 (fixed value). The Abbe number in the HI mode may be changed in increments of 5 ranging from 30 to 60 (Default setting: 35). AUTO HI MODE CYL STEP R PRISM PRISM AXIS SPH CYL AXIS ADD e. AUTO HOLD ON: AUTO HOL…
-
2, Tomey TL-100 SYMBOLS USED IN THIS MANUAL The symbols used in this manual represent the following messages: • This is a precaution that, if unheeded, will result in a hazard- ous situation where there is an imminent danger of serious injury or death. • This is precaution that…
-
26, 3-11 e. In AUTO mode, a beep will sound, and the ADD reading will be held automatically. In Manual mode, press the HOLD button. If the near zone of a progressive addition lens is located very close to the frame, the cross cursor (+) may not change to » &quo…
-
55, 5-4 5.1 TROUBLESHOOTING GUIDE Cause 3: The near point area in a small frame lens may be positioned very near to the edge of the frame or even outside of the frame. It may not be possible to detect the near point area in such lenses. Action: Press HOLD button when jud…
-
Tomey TL-100 User Manual
-
Tomey TL-100 User Guide
-
Tomey TL-100 PDF Manual
-
Tomey TL-100 Owner’s Manuals
Recommended Products:
Citiz, Z120, SPEAKEASY COMBO 2005 TRIPLE, ID-3000, ThinkCentre M50e, KM 6366-1
Compatible Medical Equipment Devices:
Popular Right Now:
Operating Impressions, Questions and Answers: